agenitor | 80 to 450 kW

agenitor.

The highly efficient 2G plant with optimised gas motor -
reduces fuel costs.

220 to 450 kW

The agenitor by 2G. Reliable top performance for maximum earnings.

The agenitor series by 2G is available in the output range from 220 kW to 450 kW. Both natural gas and biogas can be used as fuel.

 

The development team at 2G Drives GmbH, 2G Energy AG's research and development company, has achieved excellent results in terms of the efficiency of combined heat and power plants by optimising gas motor technology. The use of steel pistons has greatly reduced frictional power and heat losses. The four-valve technology enables highly efficient gas exchange in the combustion chamber. A micro-processor controlled ignition system ensures that the ignition time and ignition energy are optimally adjusted to the gas quality.

 

These measures significantly increased the efficiency level. Both the agenitor 406 (250 kW electrical) and the agenitor 408 (360 kW electrical) now have an electrical efficiency level of 42.5 percent putting them at the top of their respective output classes in the world. For the operator of the CHP plant, a higher efficiency level means: lower gas consumption, lower fuel costs, higher yield.

 

Thanks to heavy duty motor components, the agenitor is also very reliable in regular start-stop operation.

 

The agenitor. Versatile applications.

Whether in the food industry, in a hospital, consumer market, hotel or leisure part, agenitor combined heat and power plants are amongst the most reliable in the world and help reduce energy consumption, energy costs and carbon dioxide emissions.

 

At the Europa-Park Rust, one of the most beautiful leisure parks in the world, two agenitor plants help keep energy consumption as low as possible. In Latvia, five agenitor 212 CHP plants installed in series also operate reliably in winter at -32 °C. All the heat produced is fed into a heating grid. At the Kempinsky Berchtesgaden, a luxury hotel, an agenitor 406 contributes to the electricity and heat supply. At the juice manufacturer albi, two agenitor 406 in combination with a steam generator and an absorption chiller supply process heat and steam.

 

The agenitor at a glance.

  • Innovative CHP series for operation with natural gas and biogas, 220 kW to 450 kW electrical
  • Highly efficient plant with optimised gas motor, and therefore lower fuel costs
  • Designed as a turn-key compact module
  • Modular assembly facilitates installation in less accessible locations
  • Thanks to heavy duty motor components, also very reliable in regular start-stop operation
  • Robust and low maintenance

 

agenitor. 100 to 450 kW. Natural gas

 Type   Output Electrical level
  Configuration Electrical Thermal Electrical Thermal Overall
agenitor 404 bt80-0 100 kW 112 kW 38.4 % 42.9 % 81.3 %
bt70-0 95 kW 108 kW 38.2 % 43.2 % 814 %
ct80-0 160 kW 168 kW 41.0 % 43.0 % 84.0 %
ct70-0 160 kW 172 kW 40.4 % 43.5 % 84.0 %
agenitor 206 ct80-0 220 kW 253 kW 39.6 % 45.5 % 85.1 %
agenitor 306 ct80-0 250 kW 290 kW 39.8 % 46.2 % 86.0 %
agenitor 406 bt80-0 250 kW 304 kW 39.8 % 48.3 % 88.1 %
ct80-0 250 kW 260 kW 41.8 % 43.5 % 85.3 %
ct70-0 250 kW 277 kW 39.5 % 43.7 % 83.2 %
agenitor 408 ct80-0 360 kW 381 kW 42.5 % 45.0 % 87.5 %
ct70-0 330 kW 356 kW 42.2 % 45.6 % 87.8 %
agenitor 312 ct80-0 450 kW 482 kW 40.9 % 43.7 % 84.6 %
ct70-0 450 kW 500 kW 38.3 % 42.5 % 80.8 %
agenitor 412 ct70-0 450 kW 493 kW 41.3 % 45.3 % 86.6 %

agenitor. 75 to 450 kW. Biogas

Type   Output Electrical level
  Configuration Electrical Thermal Electrical Thermal Overall
agenitor 404 at135-0* 75 kW 85 kW 38,0 % 43,0 % 81,0 %
bt135-0 100 kW 110 kW 38,6 % 42,4 % 81,0 %
ct135-0 160 kW 155 kW 41,5 % 40,2 % 81,7 %
agenitor 206 ct130-0 220 kW 232 kW 40,6 % 42,8 % 83,4 %
agenitor 306 ct130-0 250 kW 265 kW 41,0 % 43,5 % 84,5 %
agenitor 406 ct135-0 250 kW 245 kW 42,5 % 41,6 % 84,1 %
agenitor 408 ct135-0 360 kW 345 kW 42,5 % 40,7 % 83,2 %
agenitor 212 ct130-0 400 kW 445 kW 40,1 % 44,6 % 84,7 %
agenitor 312 ct130-0 450 kW 470 kW 40,5 % 42,3 % 82,8 %
agenitor 412 ct135-0 450 kW 468 kW 41,1 % 42,7 % 83,8 %
Info for download.

Info for download.

For all CHP plants by 2G: Output range, efficiency level, fields of use, set-up possibilities, noise protection etc.

Download Brochure
The agenitor in use.

The agenitor in use.

In the food industry, in trade establishments, in hospitals and even in a zoo.

To references
Make an enquiry.

Make an enquiry.

Do you want to produce your own electricity and heat and reduce energy costs for your business in the long-term?

Get in touch

Customer Support
Please contact

+49 (0) 2568 9347 2199

24hr service hotline for
Installations from 50kW

+49 (0) 2568 9347 - 0

Top service

You are fully protected with a premium service contract.
With full cost control.